Jiangxi Dasen Mining Industry Co.
-
+86-18270853858

IS125-80-200A Bomba de agua limpia
Descripción
1. Basic specification model analysis:
IS: International standard single-stage single- suction centrifugal pump
125: Inlet diameter 125mm (DN125)
80: Outlet diameter 80mm (DN80)
200A: Impeller nominal diameter 200mm (A indicates the first cutting of the impeller)
Type: Horizontal axial suction centrifugal pump
Standard: GB/T5657 (equivalent to ISO2858)
2. Performance parameters
| parámetro | Indicator range |
| Flow(Q) | 60-120m³/h |
| Head (H) | 40-55m |
| rated speed | 2900r/min (2-pole motor) |
| efficiency | 68-72% |
| Required NPSH | 3.0-4.0m |
3.Structural design
Pump body material:
Standard: HT200 cast iron
Optional: 304 stainless steel(corrosive environment)
Impeller:
Closed structure (dynamic balance G6.3 level)
Material:cast iron/bronze (optional)
Shaft seal:
Standard: packing seal (graphite impregnation)
Upgrade: single end mechanical seal (standard flushing port)
4.Power configuration
Matching motor:
Power: 18.5-30kW (selected according to working conditions)
Protection level: IP54/IP55
Insulation class: Class B/Class F
Transmission mode: Direct coupling (elastic pin type)
5. Installation parameters
| Artículo | Dimensions (mm) |
| Center height | 250 |
| Inlet and outle flange | GB/T9113 PN16 |
| Foot spacing | 500×400 |
| Total length | ≈850 |
6. Operation limit
medium temperature: ≤80℃(high temperature type can reach 120℃)
Working pressure: ≤1.0MPa
Solid content: ≤0.1% (clean water standard)
7.Selection and expansion
Special configuration:
Variable frequency motor (energy-saving adjustment)
Full set of stainless steel materials (food/ pharmaceutical grade)
Motor antideflagrante (Ex dⅡ BT4)
Escenarios típicos de aplicación
1. Building water supply system
2. Fire water supply
3. Industrial circulating water
4. Air conditioning cooling water system
(Note: The actual selection needs to check the pipeline characteristic curve, and it is recommended to reserve 10% flow margin)