Jiangxi Dasen Mining Industry Co., Ltd.
-
+86-18270853858

6m³ Cyanide Storage Tank
Description
1.Basic specifications
Effective volume: 6m³ (actual volume is about 6.5m³ including top space)
Design criteria:
GB 18564.12019 (Road Transport of Dangerous Liquid Goods Tanks)
HG/T 205692013 (Design Specification for Chemical Equipment)
2.Structural parameters
Item | parameter |
Tank Type | Vertical flat bottom/conical bottom (with drain outlet) |
Diameter x height | Φ 1800 × 3000mm (typical size) |
wall | 8-12mm (316L stainless steel) |
Thickness | Normal pressure (-0.5~+2kPa) |
Working Pressure Design Temperature | -20℃~+120℃ |
3.Material configuration
Main Material:
Standard: 316L stainless steel (UNS S31603) Reinforced: 316L+PTFE lining (2mm thick) Sealing system:
Double flange manhole (DN600, with nitrogen sealing interface)
Mechanical breathing valve (anti-negative pressure/overpressure)
4.Safety accessories
configuration | TECHNICAL INDEX |
Leak detection | Tank bottom HCN gas sensor (0-50ppm) |
Emergency | Blasting disc (0.3MPa)+diversion pipe |
discharge cleaning | Rotating spray ball (CIP cleaning) |
system level monitoring | Radar level gauge (± 1mm accuracy) |
5.Special design
Anti-crystallization measures:
Tank electric heating (50W/m, maintained at 40-60℃)
Side wall vibrator (to prevent NCN crystal deposition)
Anti-corrosion reinforcement: Weld pickling passivation treatment Cathodic protection
(optional)
6.Environmental adaptation
Explosion-proof level: Ex dⅡ BT4 (overall explosion-proof design)
Seismic level: Level 8 (GB 50011-2010)
Protection level: IP65(outdoor type)
7.Selection recommendations
1. High concentration cyanide (≥30%): PTFE lining + nitrogen blanketing system must be selected
2. Mobile storage tank:
Must comply with GB 18564.1 standard and be equipped with wave-proof plates
3.Maintenance cycle:
Monthly: Leakage test
Annual: Wall thickness ultrasonic test
(Note: The actual selection requires the specific composition, concentration and ambient temperature